MIRRANT  AUTOMATION  PVT. LTD.
PH ANALYSER

PH 4100

Designed for Continuous Monitoring and Measurement of pH

PH 4100 - PH ANALYSER

PH 4100 is a pH analyser is a microprocessor based online analytical instrument designed for continuous monitoring and measurement of pH. It provides reliable real-time process monitoring and is suitable for a wide range of industrial water treatment and process control applications.

Widely used in industries such as power generation, chemical processing, fertilizer plants, metallurgy and municipal water treatment, the controller ensures accurate and stable measurement for efficient process management and quality control.


KEY HIGHLIGHTS

  • Continuous online pH monitoring
  • High measurement accuracy and stability
  • Digital display of pH and temperature
  • Relay outputs for alarm and control functions
  • Suitable for harsh industrial environments
Water quality analyser Ph analyser Ph measurement PH meter PH sensor

Specification

Accuracy ± 0.02pH or ±1% FS Resolution 0.01pH
Measuring range 0~14pH Power supply 230V AC, 24V DC
Signal output 4-20mA, Relays Communication RS 485 Modbus RTU
Display 3.2 - inch LCD display Electrical interface 3 M12*1.5 cable Gland
Enclosure Material ABS Transmitter IP Class IP 66
Installation Cabinet panel
Model No PH 4100 - P pH range 0~14pH
Indicator Electrode Low impedance hemispherical glass membrane Reference System Ag/AgCl reference electrode
Electrode Material PPS + glass + Porous PTFE diaphragm Working Temperature 0~100°C
Working Pressure 2 Bar Sample flow rate 0.001m/s ~ 0.5m/s
Zero (E0) pH pH 6.86 buffer solution: 6.86±0.3 pH Slope% pH 4.01 pH 6.86 buffer solution >95%
Temperature Unit PT1000, NTC10K Thread size 1" NPT
Dimension Diameter – 35mm, Length – 200mm Cable 5 mtrs, 10 mtrs
Model No PH 4100 - G pH range 0~14pH
Indicator Electrode Hemispherical membrane Reference System Ag/AgCl, Double salt bridge, KCl gel
Electrode Material Glass + Annular ceramic hole, Glass + Porus ceramic sand core Working Temperature 0~80°C
Working Pressure 2 Bar Sample flow rate 0.001m/s ~ 0.5m/s
Zero Position ±0.25pH@25°C Slope% >95%@25°C
Temperature Unit PT1000, NTC10K, PT100 Electrode Dimension Diameter – 12mm, Length – 120mm
Lead type Integrated or separate FS8, FVP etc. Cable Length 5 mtrs, 10 mtrs
Model No PH 4100 - S pH range 0~14pH
Resolution 0.01 pH Accuracy 0.1% of measuring range
Response speed T90<10s Calibration method Standard calibration – Zero calibration, slope calibration, contrast deviation calibration
Working Pressure 2 Bar Operating Temperature 5°C to +50°C (non-freezing)
Storage Temperature 0°C to +60°C (non-freezing) Main Material POM + SS 316L or Titanium alloy
Cable Length 5 mtrs, 10 mtrs

  • Accuracy ± 0.02pH or ±1% FS
  • Resolution 0.01pH
  • Measuring range 0~14pH
  • Power supply 230V AC, 24V DC
  • Signal output 4-20mA, Relays
  • Communication RS 485 Modbus RTU
  • Display 3.2 - inch LCD display
  • Electrical interface 3 M12*1.5 cable Gland
  • Enclosure Material ABS
  • Transmitter IP Class IP 66
  • Installation Cabinet panel

  • Model No PH 4100 - P
  • pH range 0~14pH
  • Indicator Electrode Low impedance hemispherical glass membrane
  • Reference System Ag/AgCl reference electrode
  • Electrode Material PPS + glass + Porous PTFE diaphragm
  • Working Temperature 0~100°C
  • Working Pressure 2 Bar
  • Sample flow rate 0.001m/s ~ 0.5m/s
  • Zero (E0) pH pH 6.86 buffer solution: 6.86±0.3 pH
  • Slope% pH 4.01 pH 6.86 buffer solution >95%
  • Temperature Unit PT1000, NTC10K
  • Thread size 1" NPT
  • Dimension Diameter – 35mm, Length – 200mm
  • Cable 5 mtrs, 10 mtrs

  • Model No PH 4100 - G
  • pH range 0~14pH
  • Indicator Electrode Hemispherical membrane
  • Reference System Ag/AgCl, Double salt bridge, KCl gel
  • Electrode Material Glass + Annular ceramic hole, Glass + Porus ceramic sand core
  • Working Temperature 0~80°C
  • Working Pressure 2 Bar
  • Sample flow rate 0.001m/s ~ 0.5m/s
  • Zero Position ±0.25pH@25°C
  • Slope% >95%@25°C
  • Temperature Unit PT1000, NTC10K, PT100
  • Electrode Dimension Diameter – 12mm, Length – 120mm
  • Lead type Integrated or separate FS8, FVP etc.
  • Cable Length 5 mtrs, 10 mtrs

  • Model No PH 4100 - S
  • pH range 0~14pH
  • Resolution 0.01 pH
  • Accuracy 0.1% of measuring range
  • Response speed T90<10s
  • Calibration method Standard calibration – Zero calibration, slope calibration, contrast deviation calibration
  • Working Pressure 2 Bar
  • Operating Temperature 5°C to +50°C (non-freezing)
  • Storage Temperature 0°C to +60°C (non-freezing)
  • Main Material POM + SS 316L or Titanium alloy
  • Cable Length 5 mtrs, 10 mtrs

Reliable Performance

Built for accurate and stable measurement

Global Standards

Designed to meet international standards

Easy Integration

Seamless integration with control systems

Expert Support

Get expert support for selection & application

GET IN TOUCH

Our experts are here to help you identify the right solution for your application.