MIRRANT  AUTOMATION  PVT. LTD.
TDS-Conductivity Analyser

TDS 4200

Measure the Electrical Conductivity & Total Dissolved Solids in a Liquid

TDS 4200 - TDS/CONDUCTIVITY ANALYSER

TDS 4200 is a TDS/Conductivity analyser an instrument used to measure the electrical conductivity and Total Dissolved Solids in a liquid. Conductivity indicates the ability of a solution to conduct electric current, which depends on the concentration of dissolved ions such as salts, acids, alkalis, and other conductive substances.

These analysers are widely used in water treatment plants, power plants, pharmaceutical industries, food and beverage processing, chemical manufacturing, and environmental monitoring to assess water purity and process efficiency.


KEY HIGHLIGHTS

  • Wide conductivity measuring range
  • High measurement accuracy and stability
  • Real time continuous online monitoring
  • Digital display with user friendly interface
  • Compact and rugged industrial design
Water quality analyser TDS Analyser Conductivity Analyser TDS meter Conductivity meter conductivity sensor

Specification

Accuracy ± 1% of measuring range Resolution 0.01μS /cm / 0.001mg/L
Conductivity Display Range 0.00μS /cm ~ 500mS/cm TDS Display Range 0.000mg/L~ 500g/L
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC Power Supply 230V AC, 24V DC
Output 2 settable 0/4~20mA active current loop outputs, max load 1000Ω Communication RS485 MODBUS RTU, HART
Time/Data Record Record 10000 historical data Operating Temperature 0 ~ 60°C, RH<95%
Shell Material Enhanced ABS Protection IP Class IP 66
Dimension 100*100*120 mm Mounting Method Wall mounting, pipe clamping, panel (hole size 138*138 mm)
Model No TDS 4200 - P Accuracy ± 1% FS
Resolution 0.01μS/cm Measuring Range Conductivity: 0~10mS/cm, TDS: 0~5g/L
Power Supply 24V DC Response Time T90<15s
Temperature Compensation Automatic, built-in temperature unit Calibration Method Multi-point calibration; Contrast Offset; Factor offset
Operating Temperature 0~50°C Operating Pressure 2 Bar
Shaft Material PPS Dimensions Diameter 35mm/Total length 230 mm
Protection IP Class IP 68 Installation Method 1 inch NPT at both ends; Immersed or piped installation
Sensor Cable Length 5 mtrs, 10 mtrs
Model No TDS 4200 - A Principle Graphite 2-pole
Signal Type Analog K Constant K = 1
Measuring Range 0~10 mS/cm Temperature Compensation PT1000
Working Pressure 2 Bar Operating Temperature 0~60°C@4Bar, 0~80°C@2Bar
Shaft Material ABS Protection IP Class IP 68
Dimensions Diameter 35mm/length 200 mm Installation Method 1" NPT
Cable 5 mtrs, 10mtrs
Model No TDS 4200 - S Signal Type Analog
Principle 2-electrode K Constant 0.1
Measuring Range 0.5~200μS/cm Temperature Compensation PT1000
Working Pressure 2 Bar Operating Temperature 0~50°C
Shaft Material SS 316L Protection IP Class IP 68
Dimensions Diameter 13.4mm/length 125 mm Installation Method ½" NPT
Cable 5 mtrs, 10 mtrs
Model No TDS 4200 - I Signal Type Analog
Principle Inductive Toroidal Sensing Measuring Range 0~2000mS/cm
Temperature Compensation PT1000 Working Pressure 2 Bar
Operating Temperature 0~50°C Shaft Material PP
Protection IP Class IP 68 Installation Method Insertion Type
Cable 5 mtrs, 10 mtrs

  • Accuracy ± 1% of measuring range
  • Resolution 0.01μS /cm / 0.001mg/L
  • Conductivity Display Range 0.00μS /cm ~ 500mS/cm
  • TDS Display Range 0.000mg/L~ 500g/L
  • Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
  • Power Supply 230V AC, 24V DC
  • Output 2 settable 0/4~20mA active current loop outputs, max load 1000Ω
  • Communication RS485 MODBUS RTU, HART
  • Time/Data Record Record 10000 historical data
  • Operating Temperature 0 ~ 60°C, RH<95%
  • Shell Material Enhanced ABS
  • Protection IP Class IP 66
  • Dimension 100*100*120 mm
  • Mounting Method Wall mounting, pipe clamping, panel (hole size 138*138 mm)

  • Model No TDS 4200 - P
  • Accuracy ± 1% FS
  • Resolution 0.01μS/cm
  • Measuring Range Conductivity: 0~10mS/cm, TDS: 0~5g/L
  • Power Supply 24V DC
  • Response Time T90<15s
  • Temperature Compensation Automatic, built-in temperature unit
  • Calibration Method Multi-point calibration; Contrast Offset; Factor offset
  • Operating Temperature 0~50°C
  • Operating Pressure 2 Bar
  • Shaft Material PPS
  • Dimensions Diameter 35mm/Total length 230 mm
  • Protection IP Class IP 68
  • Installation Method 1 inch NPT at both ends; Immersed or piped installation
  • Sensor Cable Length 5 mtrs, 10 mtrs

  • Model No TDS 4200 - A
  • Principle Graphite 2-pole
  • Signal Type Analog
  • K Constant K = 1
  • Measuring Range 0~10 mS/cm
  • Temperature Compensation PT1000
  • Working Pressure 2 Bar
  • Operating Temperature 0~60°C@4Bar, 0~80°C@2Bar
  • Shaft Material ABS
  • Protection IP Class IP 68
  • Dimensions Diameter 35mm/length 200 mm
  • Installation Method 1" NPT
  • Cable 5 mtrs, 10mtrs

  • Model No TDS 4200 - S
  • Signal Type Analog
  • Principle 2-electrode
  • K Constant 0.1
  • Measuring Range 0.5~200μS/cm
  • Temperature Compensation PT1000
  • Working Pressure 2 Bar
  • Operating Temperature 0~50°C
  • Shaft Material SS 316L
  • Protection IP Class IP 68
  • Dimensions Diameter 13.4mm/length 125 mm
  • Installation Method ½" NPT
  • Cable 5 mtrs, 10 mtrs

  • Model No TDS 4200 - I
  • Signal Type Analog
  • Principle Inductive Toroidal Sensing
  • Measuring Range 0~2000mS/cm
  • Temperature Compensation PT1000
  • Working Pressure 2 Bar
  • Operating Temperature 0~50°C
  • Shaft Material PP
  • Protection IP Class IP 68
  • Installation Method Insertion Type
  • Cable 5 mtrs, 10 mtrs

Reliable Performance

Built for accurate and stable measurement

Global Standards

Designed to meet international standards

Easy Integration

Seamless integration with control systems

Expert Support

Get expert support for selection & application

GET IN TOUCH

Our experts are here to help you identify the right solution for your application.